Seamless Copper Tube for Air Conditioning and Refrigeration Field Service B280 UNS No 12000

Product info

Supplier: Tapgroup internation.,JSC
Address: Số 32 Lô N4D, đường X2A, Yên Sở, Hoàng Mai, Hà Nội
Phone: 0084 933 86 77 86
Email: info@tapgroup.vn
Website: https://supplier-pipe-tube-ongthep.com
Insurance: 12 tháng
Status: Mới 100%
Origin: China, Korea, Malaysia, Thailand, Japan, EU, G7
Name:  Seamless Copper Tube for Air Conditioning and Refrigeration Field Service B280 UNS No 12000
 Type Of Tubes SMLS Copper Tube B280 UNS No 12000
Standard Specification for Seamless Copper Tube for Air Conditioning and Refrigeration Field Service
This standard is issued under the fixed designation B 280; the number immediately following the designation indicates the year of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A superscript epsilon (E) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense. 
Scope
This specification establishes the requirements for seamless copper tube intended for use in the connection, repairs, or alternations of air conditioning or refrigeration units in the field.
NOTE 1—Fittings used for soldered or brazed connections in air conditioning and refrigeration systems are described in ASME Standard B16.22.
NOTE 2—The assembly of copper tubular systems by soldering is described in Practice B 828.
NOTE 3—Solders for joining copper tubular systems are described in Specification B 32. The requirements for acceptable fluxes for these systems are described in Specification B 813.
The tube shall be produced from the following coppers, and the manufacturer has the option to supply any one of them, unless otherwise specified: 
Copper UNS No. Previously Used Designation Description
C12000 DLP Phosphorus deoxidized, low residual phosphorus
The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
The following hazard statement pertains only to the test method described in Section 18.2.4 of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Materials and Manufacture
Materials—The material of manufacture shall be billets, bars, or tube and shall be of such soundness as to be suitable for processing into the tubular products described.
Manufacture: The tube shall be manufactured by such hot or cold working processes as to produce a homogeneous uniform wrought structure in the finished product. The tube shall be cold drawn to the finished size and wall thickness.
Coiled lengths specified O60, soft annealed temper, shall be bright annealed after coiling, then dehydrated, and capped, plugged, crimped, or otherwise closed at both ends so as to maintain the internal cleanness of the tubing under normal conditions of handling and storage.
Straight lengths specified H58 hard-drawn temper shall be cleaned and capped, plugged, or otherwise closed at both ends so as to maintain the internal cleanness of the tubing under normal conditions of handling and storage.
Chemical Composition
The chemical composition shall conform to the chemical requirements for the specific type of copper.
These limits do not preclude the presence of other elements. When included in the contract or purchase order, and agreed upon by the manufacturer or supplier and the purchaser, limits shall be established and analysis required for unnamed elements.
Chemical Composition—Weight %
Element Copper UNS No
C12000
Copper,B min 99.90
Phosphorus 0.004-0.012
A Oxygen shall be 10 ppm max.
 
B Copper + silver.
Temper
Product under this specification shall be furnished in either O60 (soft annealed) or H58 (drawn general purpose) temper, as specified in the contract or purchase order and defined in Classification B 601.
Coils are normally furnished in O60 temper and straight lengths in H58 temper.
Grain Size
Coiled lengths shall be furnished in the O60 temper and shall have a recrystallized grain size of 0.040 mm minimum when determined in accordance with Test Methods E 112.
Tensile Requirements
The tube shall conform to the tensile requirements prescribed.
Form Temper Designation Tensile Strength, min Elongation in 2 in. (50.8 mm), min, %
Standard   Former ksiA MPaB
Coiled lengths O60 soft annealed 30 205 40
Straight lengths H58 drawn general
purpose
36 250  
A ksi = 1000 psi.
B See Appendix X1.
 Nondestructive Testing
Electromagnetic (Eddy-Current) Examination:
Each straight length of tube up to and including 31/s in. (79.4 mm) in outside diameter, shall be subjected to examination.
Tubes that do not actuate the signaling device on the testing unit, after having been adjusted to provide information on the suitability of the tube for the intended application, shall conform to the requirements of this test. Testing shall be in accordance with Practice E 243.
Testing of coiled lengths shall be subject to negotia-tion between the manufacturer and the purchaser.
For tubes too large for the testing unit, the test method to be used shall be by agreement between the manufacturer and the purchaser.
Dimensions, Mass, and Permissible Variations
The standard dimensions and weights per foot for the various nominal sizes.
Wall Thickness and Diameter—The tolerances for wall thickness and diameter shall conform to the requirements specified.
Lengths and Tolerances:
Standard Lengths and Tolerances—The standard length for coils shall be 50 ft (15.2 m). The length tolerances for 50-ft coils shall be +12 in. (305 mm) and -0 in. The standard length for straight lengths shall be 20 ft (6.1 m). The length tolerances for 20-ft lengths shall be +1 in. (25 mm) and -0 in.
Tubes supplied in other than standard lengths and tolerances shall be in accordance with requirements established by agreement between the manufacturer or supplier and the purchaser.
Roundness—For drawn unannealed tube in straight lengths, the roundness tolerance as specified. The deviation from roundness is measured as the difference be-tween major and minor diameters as determined at any one cross section of the tube. Roundness tolerance has not been established for annealed tube in straight lengths nor for tubes furnished in coils.
Squareness of Cut—For tube in straight lengths, the departure from squareness of the end of any tube shall not exceed more than 0.010 in. (0.25 mm) for tube up to and including 5/s-in. (15.9-mm) standard size; and not more than 0.016 in./in. (0.016 mm/mm) of outside diameter, for tube larger than 5/s-in. standard size.
For the purpose of determining conformance with the dimensional requirements prescribed in this specification, any measured value outside the specified limiting values for any dimension shall be subject to rejection.
Standard Dimensions and Weights, and Tolerances in Diameter and Wall Thickness for Straight Lengths
Applicable to drawn temper tube only.
Standard Size, in. Outside Diameter, in. (mm) Wall Thickness, in. (mm) Weight, lb/ft (kg/m) Tolerances
AverageA Outside Diameter, Plus and Minus,in. (mm) WallB Thickness, Plus and Minus,in. (mm)
   3/8  0.375 (9.52) 0.030 (0.762) 0.126 (0.187) 0.001    (0.025) 0.003 (0.08)
  1/2 0.500 (12.7) 0.035 (0.889) 0.198 (0.295) 0.001    (0.025) 0.004 (0.09)
  5/8 0.625 (15.9) 0.040 (l.02) 0.285 (0.424) 0.001    (0.025) 0.004 (0.10)
  3/4 0.750 (l9.l) 0.042 (l.07) 0.362 (0.539) 0.001    (0.025) 0.004 (0.11)
  7/8 0.875 (22.3) 0.045 (l.14) 0.455 (0.677) 0.001    (0.025) 0.004 (0.11)
1  1/8 1.125 (28.6) 0.050 (l.27) 0.655 (0.975) 0.0015 (0.038) 0.004 (0.13)
1  3/8 1.375 (34.9) 0.055 (l.40) 0.884 (l.32) 0.0015 (0.038) 0.006 (0.14)
1  5/8 1.625 (41.3) 0.060 (l.52) 1.14 (1.70) 0.002 (0.051) 0.006 (0.15)
2  1/8 2.125 (54.0) 0.070 (i.7b) 1.75 (2.60) 0.002 (0.05l) 0.007 (0.18)
2  5/8 2.625 (66.7) 0.080 (2.03) 2.48 (3.69) 0.002 (0.05l) 0.008 (0.20)
3  1/8 3.125 (79.4) 0.090 (2.29) 3.33 (4.96) 0.002 (0.05l) 0.009 (0.23)
3  5/8 3.625 (92.l) 0.100 (2.54) 4.29 (6.38) 0.002 (0.05l) 0.010 (0.25)
4  1/8 4.125 (l05) 0.110 (2.79) 5.38 (b.01) 0.002 (0.05l) 0.011 (0.28)
A The average outside diameter of a tube is the average of the maximum and minimum outside diameters as determined at any one cross section of the tube.
B The tolerances listed represent the maximum deviation at any point.
Standard Dimensions and Weights, and Tolerances in Diameter and Wall Thickness for Coil Lengths
Standard Size, in. Outside Diameter, in. (mm) Wall Thickness, in. (mm) Weight, lb/ft (kg/m) Tolerances
Average^ Outside Diameter, Plus and Minus,in. (mm) WallB Thickness, Plus and Minus ,in. (mm)
   1/8  0.125 (3.18) 0.030 (0.762) 0.0347 (0.0516) 0.002 (0.051) 0.003 (0.08)
   3/16 0.187 (4.75) 0.030 (0.762) 0.0575 (0.0856) 0.002 (0.051) 0.003 (0.08)
   1/4  0.250 (6.35) 0.030 (0.762) 0.0804 (0.120) 0.002 (0.051) 0.003 (0.08)
   5/16 0.312 (7.92) 0.032 (0.813) 0.109 (0.162) 0.002 (0.051) 0.003 (0.08)
   3/8  0.375 (9.52) 0.032 (0.813) 0.134 (0.199) 0.002 (0.051) 0.003 (0.08)
   1/2  0.500 (12.7) 0.032 (0.813) 0.182 (0.271) 0.002 (0.051) 0.003 (0.08)
   5/8  0.625 (15.9) 0.035 (0.889) 0.251    (0.373) 0.002 (0.051) 0.004 (0.11)
   3/4  0.750 (19.1) 0.035 (0.889) 0.305 (0.454) 0.0025 (0.064) 0.004 (0.11)
   7/8  0.875 (22.3) 0.045 (1.14) 0.455 (0.677) 0.003 (0.076) 0.004 (0.11)
1   1/8  1.125 (28.6) 0.050 (1.27) 0.655 (0.975) 0.0035 (0.089) 0.005 (0.13)
1   3/8  1.375 (34.9) 0.055 (1.40) 0.884 (1.32) 0.004 (0.10) 0.006 (0.15)
1   5/8  1.625 (41.3) 0.060 (1.52) 1.14    (1.70) 0.0045 (0.11) 0.006 (0.15)
A The average outside diameter of a tube is the average of the maximum and minimum outside diameters as determined at any one cross section of the tube.
B The tolerances listed represent the maximum deviation at any point.
Roundness Tolerance
Applicable to drawn unannealed straight length tube only.
t/D (Ratio of Wall Thickness to Nominal Outside Diameter) Roundness Tolerance Percent of Nominal Outside Diameter (Ex-pressed to Nearest 0.001 in. or 0.010 mm)
0.01 to 0.03, incl 1.5
Over 0.03 to 0.05, incl 1.0
Over 0.05 to 0.10, incl 0.8
 Number of Tests and Retests
Tests:
Chemical composition shall be reported as the aver-age of results from at least two replicate determinations for each specified element and each determination must meet specification requirement.
Tensile and grain size shall be reported as the average of results from the specimens tested and all specimens must conform to specification requirements.
Specimens for all other tests must meet specification requirements.
Retest:
When test results obtained by the purchaser fail to conform with the product specification requirement(s), the manufacturer or supplier shall have the option to perform a retest.
Retesting shall be as directed in the product specifi-cation for the initial test except for the number of test specimens which shall be twice that normally required for the test. Test results for all specimens shall conform to the product specification requirement(s) in retest and failure to comply shall be cause for lot rejection.
Sampling Schedule
Each sample piece shall be taken from a separate tube.
Number of Pieces in Lot Number of Sample Pieces to be Taken
1 to 50 1
51 to 200 2
201 to 1500 3
Over 1500 0.2 % of total number of pieces in the lot, but not to exceed 10 pieces
Significance of Numerical Limits
For purposes of determining compliance with the specified limits for requirements of the properties listed in the following table, an observed value or a calculated value shall be rounded as indicated in accordance with the rounding method of Practice E 29:
Property Rounded Unit for Observed or Calculated Value
Chemical composition nearest unit in the last right-hand place of figures of the specified limit 
Tensile strength  nearest ksi (5 MPa)
Elongation nearest 1 %
Grain size:  
Up to 0.055 mm, incl  nearest multiple of 0.005 mm 
Over 0.055 to 0.160 mm, incl nearest 0.01 mm
tapgroup

Mr. Thi

tapgroup Email: theptangiabao@gmail.com
tapgroup Skype:
tapgroup Hotline/ Zalo/ Wechat: +84 982 384 688
tapgroup

Ms. Hoa

tapgroup Email: theptangiabao@gmail.com
tapgroup Skype:
tapgroup Hotline/ Zalo/ Wechat: +84 982 803 586
tapgroup

Ms. Phương

tapgroup Email: theptangiabao@gmail.com
tapgroup Skype:
tapgroup Hotline/ Zalo/ Wechat: +84 971 567 341
tapgroup

Ms. Trinh

tapgroup Email: theptangiabao@gmail.com
tapgroup Skype:
tapgroup Hotline/ Zalo/ Wechat: +84 971 567 943
tapgroup

Ms. Trân

tapgroup Email: theptangiabao@gmail.com
tapgroup Skype:
tapgroup Hotline/ Zalo/ Wechat: +84 971 567 954
tapgroup